SN — Sterile intradermal needle

Intradermal needle SN —
stops in the dermis even when inserted perpendicularly

A single-use sterile needle for vaccines, skin reaction tests and aesthetic intradermal injection. 32 · 33 · 34G, effective length 0.7–1.7 mm, three hub types. 90° perpendicular insertion reaches the dermis precisely.

Request specs · samplesBrochure PDF
Healthcare professionals only · Korean approval being confirmed · EO sterilised · 4-year shelf life
Intradermal needle SN — integral hub type C, green 32G · black 33G
Features

Intradermal injection — simple, precise, safe

A single-use sterile needle designed to deliver solution precisely into the dermis. For healthcare professionals in medical institutions only.

90°

Perpendicular insertion

No angle to judge — press perpendicular to the skin and it stops. Less dependent on operator skill.

200 punctures

No tip rolling after puncture

No tip rolling after a 200-puncture test (manufacturer test). Lasts longer without replacement.

Double

Double grinding — minimal pain

A three-facet ground tip and surface treatment lower penetration force — faster entry, less tissue damage.

0

No exposed adhesive

No adhesive touches the patient's injection site. Premium stainless cannula, EO sterilised, 4-year shelf life.

Intradermal needle SN hubs — sheath type (green) and collar type (clear)
3 hub types

Sheath, collar, integral — three hubs by use

Hub A's depth-limiting sheath stops against the skin; hub B's wide collar presses and flattens the skin; hub C is a simple design for kit inclusion. The hub interior is optimised for minimal dead space — less residual solution, more delivered to the patient.

A sheathB collarC integralMinimal dead space
Individually packed intradermal needle SN — 32G TW 0.23 × 1.3 mm, collar type B
Ultra-fine thin-wall cannula

32 · 33 · 34G, effective length 0.7–1.7 mm

The very short effective length gives precise placement and easy handling. Three gauges with thin wall (TW) or extra-thin wall (ETW, 34G only). The three-facet tip lowers penetration force for quick insertion and less discomfort.

32G 0.23 mm33G 0.20 mm34G 0.18 mmTW · ETW
SN · 90°
Conventional hypodermic needle · 10–15°
Epidermis
Dermis
Hypodermis
Research data

Wheal size compared with a conventional hypodermic needle

Wheal size after injection into rabbit skin was compared between a conventional hypodermic needle (10–15° insertion) and the Nextech intradermal needle (90° insertion). The solution stays in the dermis without the rash or leakage seen when lifting the skin to inject. Original figure and table on brochure page 3.

Test institution: Zhejiang Chinese Medical University Animal Research CentreBrochure Fig. 1 · Table 1
Recommended application

Applications · drugs · sites · recommended hub

ApplicationsDrugsInjection siteHub
VaccinationBCG · mpox · influenza · rabies and othersLower lateral deltoid · volar forearm · upper-arm deltoid areaA · C
Skin reaction testsIntradermal agents such as antibiotics, local anaesthetics, antitoxins, antisera, enzymesLower volar forearmA · C
Medical · aesthetic injectionHydration injections · botulinum micro-injection · local anaesthesia and othersEye area · upper, mid and lower face · neck · abdomen · hands · lips · scalp and othersB
Product specification

Model codes — 3 hub types × 32 · 33 · 34G

The last two digits are the effective length (07 = 0.7 mm … 17 = 1.7 mm); suffix E means extra-thin wall (ETW). e.g. SN-B3213 = collar type B · 32G · 1.3 mm · TW.

HubGaugeModel (effective length 0.7–1.7 mm)Wall thickness
A sheath32G (0.23 mm)SN-A3207 ~ SN-A3217TW
33G (0.20 mm)SN-A3307 ~ SN-A3317TW
34G (0.18 mm)SN-A3407 ~ SN-A3417TW
34G (0.18 mm)SN-A3407E ~ SN-A3417EETW
B collar32G (0.23 mm)SN-B3207 ~ SN-B3217TW
33G (0.20 mm)SN-B3307 ~ SN-B3317TW
34G (0.18 mm)SN-B3407 ~ SN-B3417TW
34G (0.18 mm)SN-B3407E ~ SN-B3417EETW
C integral32G (0.23 mm)SN-C3207 ~ SN-C3217TW
33G (0.20 mm)SN-C3307 ~ SN-C3317TW
34G (0.18 mm)SN-C3407 ~ SN-C3417TW
34G (0.18 mm)SN-C3407E ~ SN-C3417EETW
Sterilisation · shelf life
EO · 4 years
Cannula
Medical-grade stainless steel · three-facet ground tip
Restriction
Healthcare professionals in medical institutions only
Korea
Korean medical-device approval being confirmed — performance figures disclosed within the scope of approval

Frequently asked questions

How is it different from an ordinary short needle?

The effective length is limited to 0.7–1.7 mm and the hub stops against the skin, so it enters the dermis with a perpendicular insertion — no Mantoux angle (15°) needed.

How do I choose between hubs A, B and C?

A (sheath) or C (integral) for vaccines and skin tests; B (collar) for loose skin such as the face in aesthetics. C for kit inclusion and cost priority.

When should I choose 34G ETW?

Same 34G outer diameter with a thinner wall and wider bore. Choose it for viscous solutions or to lower injection resistance. Available in 34G only.

How do I buy in Korea, and what is the lead time?

Octudex, Nextech's official Korea sales partner, handles Korean-language consultation, quotations and samples; import, sales and payment are handled by Nextech's Korean entity (Nextech Medical (Korea) Co., Ltd.). Stocked items within one month, non-stocked up to 8 weeks. Korean approval and certification status is advised on enquiry.

Supply · Octudex

Stocked items within one month,
non-stocked items up to 8 weeks.

Competitive pricing against global tier-1 suppliers; specification consultation and guidance on TDS, sterilisation and certification data in Korean.

Request specs · samplesBrochure PDF
← All needles · delivery devices
Contact

Tell us the item and the drug,
and we start with the right specification

You do not need the product code (e.g. VA-1F20L · PC-F100). Give us the container spec and intended use — Octudex narrows down the item, and Nextech Korea handles quotation and supply.

grit@octud.com010-3338-2976
01Item · code or product family (PFS · adapter · needle)
02Drug · container spec (13/20 mm vial · fill volume · viscosity)
03Expected quantity · required documents (TDS · sterilisation · ISO 10993 · DMF) · timeline
Enquiries are forwarded to Nextech KoreaSend an inquiry