Service temperature

A component has to survive sterilisation and reflow. Long-term service temperature and short-term exposure limit are different numbers.

Published values

PropertyValueSource
Polyimide — long term350 °C and abovePrincipal Company Profile
Polyimide — short term450 ℃Principal Company Profile
PEEK — continuous250 ℃Principal brochure
PI braided sheath — long term−200 to 350 °CPrincipal brochure
PI braided sheath — short term≤ 500 ℃Principal brochure
FEP heat-shrink — shrink temp130 – 250 ℃Principal Company Profile
PET heat-shrink — shrink temp100 – 240 ℃Principal Company Profile
PEBAX heat-shrink — shrink temp180 – 190 ℃Principal Company Profile

Note

The shrink temperature of a heat-shrink tube effectively decides the material choice. If it exceeds what the part inside can take, the process does not exist.

Family-typical values are not presented as specifications. Figures like a 343 °C PEEK melting point are widely quoted but are not stated in the principal’s TDS, so they are not in this table.